issue #615: ensure 4GB max_message_size is configured for task workers.
This 4GB limit was already set for MuxProcess and inherited by all descendents including the context running on the target host, but it was not applied to the WorkerProcess router. That explains why the error from the ticket is being raised by the router within the WorkerProcess rather than the router on the original target.
This commit is contained in:
parent
3c8c11b360
commit
67759371f9
|
@ -72,6 +72,8 @@ ANSIBLE_PKG_OVERRIDE = (
|
|||
u"__author__ = %r\n"
|
||||
)
|
||||
|
||||
MAX_MESSAGE_SIZE = 4096 * 1048576
|
||||
|
||||
worker_model_msg = (
|
||||
'Mitogen connection types may only be instantiated when one of the '
|
||||
'"mitogen_*" or "operon_*" strategies are active.'
|
||||
|
@ -502,6 +504,7 @@ class ClassicWorkerModel(WorkerModel):
|
|||
# with_items loops.
|
||||
raise ansible.errors.AnsibleError(shutting_down_msg % (e,))
|
||||
|
||||
self.router.max_message_size = MAX_MESSAGE_SIZE
|
||||
self.listener_path = path
|
||||
|
||||
def _on_process_exit(self):
|
||||
|
@ -692,7 +695,7 @@ class MuxProcess(object):
|
|||
self.broker = mitogen.master.Broker(install_watcher=False)
|
||||
self.router = mitogen.master.Router(
|
||||
broker=self.broker,
|
||||
max_message_size=4096 * 1048576,
|
||||
max_message_size=MAX_MESSAGE_SIZE,
|
||||
)
|
||||
_setup_responder(self.router.responder)
|
||||
mitogen.core.listen(self.broker, 'shutdown', self._on_broker_shutdown)
|
||||
|
|