echo "
<p>
For each release, please do
<ol>
<li> The general tests
<li> As many of the other test groups as possible.
</ol>
If you have experienced problems with BOINC that are not
exercised by any of these tests,
please post to the <a href=http://www.ssl.berkeley.edu/mailman/listinfo/boinc_alpha>boinc_alpha@ssl.berkeley.edu</a> email list.
<h3>General tests</h3>
<ul>
<li>
Note fraction done of existing results.
Install the new version on top of an older version.
Make sure BOINC client and manager start up.
Make sure results resume with same fraction done.
<li>
Make sure graphics work (for all apps that support graphics).
<li>
Make sure CPU time and fraction done are increasing for running apps.
<li>Check all tabs in BOINC manager, make sure data is there.
<li> Detach from a project (e.g., alpha test) and reattach.
Make sure new work gets downloaded.
<li> Let BOINC run long enough to complete a result.
Verify that output file is uploaded,
that the result is reported,
and that new work is downloaded and started.
<li> Suspend/resume features:
suspend and resume results,
file transfers, and projects.
<li> Test activity modes 'suspended', 'based on preferences', 'always'.
<li> Shut down your computer and reboot it.
Make sure client and manager start up OK.
</ul>
<h3>Clean install</h3>
<ul>
<li> Uninstall BOINC.
<li> Remove BOINC directory.
<li> Install new BOINC.
<li> Verify that client and manager run,
and manager brings up the Attach Project wizard.
<li> Attach to a project (e.g. alpha)
and make sure work is downloaded and started.
</ul>
<h3>File transfer restart</h3>
<ul>
<li> Exit BOINC in the middle of a long file download.
Note the fraction done.
Restart BOINC.
Verify that download resumes from the same point.
<li> Same, upload.
</ul>
<h3> Preferences tests</h3>
<ul>
<li> Test 'don't run when user active' preference.
<li> Test 'leave applications in memory' preference.
<li> Test scheduling period preference.
<li> Test #processors preference.
<li> Test 'use network between hours' preference.
<li> Test 'do work between hours' preference.
<li> Test venue mechanism
</ul>
<h3>Windows single-user</h3>
<ul>
<li>Check that only the administrative and installing account can
control the core client (via the BOINC manager)
and view the BOINC directory.
</ul>
<h3>Windows multi-user</h3>
<ul>
<li>Everyone should be able to view the directory. Anybody should be able to
execute the manager but only the first person who executed the manager
should have started a core client process.
</ul>
<h3>Windows service mode</h3>
<ul>
<li>Use of 'net start boinc' and 'net stop boinc' on the command line should
start and stop the core client.
<li>Use of 'net pause boinc' and 'net continue boinc' should pause and resume
the core client.
<li>The core client should be started when the machine boots up.
<li>the core client should continue processing when nobody is logged onto the
system.
<li>Manager should be able to communicate with the core client without issue.
</ul>
<h3>Tests for modem-connected computers</h3>
<ul>
<li> Do General Tests from a modem ISDN, or VPN-connected computer.
<li> Test 'confirm before connect' preference.
<li> Test 'Disconnect when done' preference.
<li> Do these tests with both single-user and Service-mode install (Windows).
</ul>
<h3>Tests for computers with personal firewalls</h3>
<li> Do General tests on a computer that uses a personal firewall
(ZoneAlarm, Symantec, Windows XP, etc.).
In your test report Comments field, indicate the type of personal firewall.
<h3>Tests for computers connected by HTTP proxy</h3>
<ul>
<li> Do General Tests on a computer connected via an HTTP proxy.
Use authentication if possible.
</ul>
<h3>Tests for computers connected by SOCKS proxy</h3>
<ul>
<li> Do General Tests on a computer connected via a SOCKS proxy.
Use authentication if possible.
</ul>
<h3>Tests for laptops</h3>
<ul>
<li> Test 'work while running on batteries' preference'
</ul>
<h3>Screensaver tests (Windows, Mac)</h3>
<ul>
<li> Test normal case
<li> Test change apps (set scheduling period to 1 min)
<li> Test 'no graphics capable apps'
<li> Test blank time
<li> Test power save modes
</ul>
<h3>BOINC Manager Attach Project Wizard</h3>
<ul>
<li> Test normal case, invalid URL, valid but non-BOINC URL,
projects that are down.
<li> Test bad password, bad username
</ul>
<h3>GUI RPC authentication</h3>
<ul>
<li> Try to connect to core client
with bad password, from host not on list, etc.
</ul>
";
?>